Flame Detectors

      Description


      Advanced Flame Detectors: Uncompromising Early Fire Detection

      In environments where fire poses an immediate and catastrophic threat, relying solely on traditional smoke or heat detection can be too late. Our state-of-the-art Flame Detectors offer unparalleled speed, accuracy, and reliability, providing critical early warning for potential fires, even in the most challenging industrial and commercial settings.

      Designed to detect the radiant energy emitted by flames, our detectors react instantly to the distinct spectral patterns of combustion, often before smoke or significant heat has developed. This rapid response is crucial for minimizing damage, protecting assets, and safeguarding lives.

      Key Features & Technologies:

      • Multi-Spectrum IR (IR3 / IR4): Utilizes multiple infrared wavelengths to analyze flame characteristics, offering the highest level of false alarm immunity against non-flame radiation sources (e.g., sunlight, hot objects, lightning).
      • UV/IR Combined Detection: Integrates both Ultraviolet (UV) and Infrared (IR) sensors to confirm the presence of a flame, enhancing detection reliability and reducing nuisance alarms.
      • Ultraviolet (UV) Detection: Specialized in detecting UV radiation emitted by most hydrocarbon fires, providing rapid detection, especially for fires with low smoke output.
      • Rapid Response Time: Detects flames within seconds of ignition, enabling immediate action and activation of suppression systems.
      • Long Detection Range: Capable of detecting flames from significant distances, providing wide area coverage and protection.
      • Wide Field of View: Offers broad coverage angles (typically 90° - 120° horizontal and vertical), minimizing the number of detectors required for a given area.
      • High False Alarm Immunity: Advanced algorithms and multi-spectrum technologies differentiate real flames from arc welding, hot processes, sunlight, lightning, and other common interference.
      • Hazardous Area Certifications: Designed and certified for use in explosive atmospheres (e.g., ATEX, IECEx, UL, FM for Class I, Division 1 & 2 zones).
      • Built-in Test (BIT) / Self-Test Functionality: Continuously monitors the detector's operational status and sensor integrity, ensuring readiness and simplifying maintenance.
      • Robust & Durable Construction: Encased in corrosion-resistant materials (e.g., 316 Stainless Steel) with high ingress protection ratings (IP66/IP67, NEMA 4X) for harsh environmental conditions.
      • Multiple Output Options: Seamless integration with Fire & Gas (F&G) control systems, PLCs, and DCS via:
        • Standard 4-20mA analog output
        • Alarm & Fault Relays
        • Modbus RTU / RS-485
        • HART Communication
      • Wide Operating Temperature Range: Reliable performance in extreme hot or cold conditions.
      • Compliance: Meets international safety standards and performance requirements (e.g., EN54-10, NFPA 72, SIL 2/3 capable).

      Benefits You Can Count On:

      • Unrivaled Speed: Detects fires at their earliest stage, allowing critical time for intervention and mitigating catastrophic outcomes.
      • Enhanced Safety: Provides superior protection for personnel and assets in high-risk environments.
      • Reduced Downtime & Costs: Prevents minor incidents from escalating into major disasters, minimizing repair costs and operational interruptions.
      • Operational Continuity: Intelligent false alarm rejection minimizes unnecessary evacuations and process shutdowns.
      • Reliability in Extreme Conditions: Engineered to perform flawlessly in challenging industrial settings, from offshore platforms to chemical plants.
      • Regulatory Compliance: Helps meet stringent safety regulations and insurance requirements for hazardous locations.
      • Ease of Integration: Flexible output options ensure compatibility with existing safety infrastructure.

      Ideal Applications:

      Our Flame Detectors are indispensable for critical infrastructure and high-risk operations including, but not limited to:

      • Oil & Gas: Onshore and offshore platforms, refineries, pipelines, storage tanks, compressor stations.
      • Chemical & Petrochemical Plants: Manufacturing facilities, processing units, solvent storage.
      • Power Generation: Turbine enclosures, generator rooms, fuel storage areas, hydrogen generation.
      • Aircraft Hangars & Airports: Fueling areas, maintenance bays.
      • Automotive & Manufacturing: Paint booths, solvent cleaning areas, robotics cells, dust collection systems.
      • Data Centers: Critical server rooms, battery storage.
      • Waste Treatment & Recycling: Landfills, biogas facilities.
      • Marine & Offshore: LNG carriers, FPSOs, cargo vessels.
      • Pharmaceutical & Biotech: Cleanrooms, storage of flammable liquids.
      • Military & Defense: Ammunition depots, vehicle depots.
      • Tunnel Ventilation Systems

      Technical Specifications (Example):

      FeatureSpecification
      Detection TypeMulti-Spectrum IR (IR3) or UV/IR
      Target FuelsHydrocarbons (n-Heptane, Methane, Hydrogen, IPA, etc.)
      Detection RangeUp to 250 ft (75m) for 1 ft² n-Heptane fire
      Response TimeTypically < 5 seconds
      Field of View100° Horizontal x 90° Vertical
      Spectral ResponseUV: 185-260 nm; IR: 1.0-2.8 µm, 4.2-4.8 µm, etc. (Multi-IR specific)
      Output Signals4-20mA (sink/source), 3x Relay (Alarm, Fault, Auxiliary), RS-485 Modbus RTU
      ApprovalsATEX, IECEx, UL, FM, cUL, CE Mark, SIL 2/3 Capable, EN54-10
      Operating Temp.-40°C to +85°C (-40°F to +185°F)
      Humidity0 to 95% RH (non-condensing)
      Enclosure Material316 Stainless Steel
      Ingress ProtectionIP66/IP67, NEMA 4X
      Power Input18-32 VDC
      Power ConsumptionTypically 3-5W
      WeightApprox. 2.5 kg (5.5 lbs)

      Tags: Flame Detectors