Model: Bionim-BI Series (e.g., Bionim-BI-150 for 150L)
Uncompromising Accuracy for Critical Microbiological Applications
The Bionim Laboratory Precision Bacteriological Incubator is engineered to provide an exceptionally stable and uniform environment, essential for the reliable growth of bacterial cultures, fungi, and other microorganisms. Designed for microbiology labs, research institutions, pharmaceutical quality control, and clinical diagnostics, the Bionim-BI Series ensures highly reproducible results, protecting your valuable samples and experimental integrity.
Key Features & Benefits:
1. Superior Temperature Control & Uniformity
Advanced PID Microprocessor Control: Delivers rapid temperature recovery, minimal overshoot, and outstanding stability, critical for sensitive cultures.
Wide Temperature Range: Operates from Ambient +5°C to 70°C, accommodating a diverse array of microbiological requirements.
Exceptional Uniformity: Forced-air circulation system ensures ±0.2°C uniformity at 37°C throughout the chamber, eliminating hot and cold spots.
High Accuracy: Maintains temperature with an accuracy of ±0.1°C, guaranteeing optimal growth conditions.
2. Robust & Hygienic Construction
High-Grade SUS304 Stainless Steel Interior: Seamless, polished chamber for easy cleaning, corrosion resistance, and sterile environment maintenance.
Durable Powder-Coated Steel Exterior: Provides a robust, long-lasting finish resistant to common laboratory chemicals and spills.
High-Density Insulation: Non-CFC, high-performance insulation minimizes heat loss, ensuring energy efficiency and stable internal temperatures.
Double-Door System:
Outer Insulated Door: With magnetic gasket seal for superior thermal retention.
Inner Tempered Glass Door: Allows visual inspection of samples without disturbing the internal environment, preventing temperature fluctuations.
3. Advanced Safety & Monitoring
Independent Over-Temperature Protection: A separate, adjustable safety thermostat with audible and visual alarms protects samples from overheating, ensuring sample integrity even in case of primary control failure.
Door Open Alarm: Notifies users if the door is left ajar, preventing temperature excursions.
Power Failure Auto-Resume: Automatically resumes operation with previous settings after a power interruption, protecting long-term experiments.
Diagnostic Self-Checks: Continuously monitors system parameters for optimal performance and alerts for potential issues.
Calibration Port: Dedicated port for easy temperature validation and calibration by external probes.
4. User-Friendly Interface & Programming
Intuitive Digital LCD/LED Display: Clear, real-time display of actual and set temperatures, remaining time, and operational status.
Easy-to-Use Control Panel: Simple, icon-driven interface for straightforward temperature setting, timer programming, and alarm configuration.
Programmable Timer: Integrated timer (e.g., 1 min to 99 hrs 59 min) for automated incubation cycles.
Lock-out Function: Prevents unauthorized changes to critical parameters.
5. Ergonomic Design & Versatility
Adjustable Perforated Stainless Steel Shelves: Maximize usable chamber space and ensure efficient air circulation around samples. Easily removable for cleaning.
Internal LED Lighting (Optional): Provides clear visibility of samples.
Stackable Design (on certain models): Saves valuable laboratory bench space.
Multiple Capacities: Available in a range of volumes (e.g., 50L, 100L, 150L, 250L, 400L) to suit various laboratory throughputs and space requirements.
Technical Specifications (Bionim-BI-150 Example):
Feature
Specification
Model
Bionim-BI-150
Temperature Range
Ambient +5°C to 70°C
Temperature Accuracy
±0.1°C at 37°C
Temperature Uniformity
±0.2°C at 37°C
Control System
PID Microprocessor
Display
Digital LCD with Backlight
Chamber Volume
150 Liters
Interior Material
SUS304 Polished Stainless Steel
Exterior Material
Powder-Coated Steel
Inner Door
Tempered Glass
Shelves
2 (Adjustable, Perforated SUS304, Max 5)
Heating Method
Forced Air Convection
Safety Features
Independent Over-Temperature Protection, Door Open Alarm, Power Failure Auto-Resume
Timer
1 min to 99 hrs 59 min
Power Supply
220V/50Hz or 110V/60Hz (Specify upon order)
Power Consumption
550W
Internal Dimensions
500 x 450 x 670 mm (W x D x H)
External Dimensions
650 x 600 x 1000 mm (W x D x H)
Net Weight
Approx. 85 kg
Certifications
CE, ISO 9001:2015
(Note: Specifications may vary slightly based on specific model capacity and regional power requirements. Customization options available.)
Applications:
Microbiology: Growth of bacteria, yeasts, and molds for identification and quantification.
Cell Culture: Incubation of non-CO2 dependent cell lines.
Pharmaceutical Testing: Stability testing, microbial limit tests, and environmental monitoring.
At Bionim Laboratory, we are committed to equipping your lab with instruments that deliver exceptional performance and reliability. The Bionim Bacteriological Incubator embodies:
Unwavering Precision: For results you can trust, every single time.
Robust Reliability: Built to last with minimal maintenance, ensuring long-term operational efficiency.
User-Centric Design: Intuitive controls and ergonomic features enhance daily workflow.
Comprehensive Safety: Protecting your valuable samples and personnel.
Dedicated Support: Backed by Bionim's commitment to customer service and technical expertise.
Invest in the Bionim Laboratory Precision Bacteriological Incubator and elevate your microbiological research and routine work to new levels of accuracy and confidence.
Contact us today for a detailed quote or to discuss your specific laboratory needs.