Fire Exit Door

      Description


      Here's a detailed product description for a Fire Exit Door in Markdown format:

      High-Performance Fire Exit Door - Ultimate Safety & Compliance

      Ensure the absolute safety of your occupants and meet critical building regulations with our state-of-the-art Fire Exit Doors. Engineered for rapid and secure emergency egress, combined with robust security features, our doors provide peace of mind in any commercial, industrial, or public building setting.

      Key Features & Benefits

      Our Fire Exit Doors are designed with life safety and durability at their core:

      • Unrestricted Egress (Panic Hardware): Equipped with high-quality panic bars (push bar or crash bar) conforming to EN 1125. This ensures immediate, single-action opening in emergencies, even under panic conditions, allowing for swift evacuation.
      • Certified Fire Resistance: Available with certified fire ratings from FD30 (30 minutes) up to FD120 (120 minutes) according to BS EN 1634. These ratings effectively compartmentalize fires, preventing the spread of fire and smoke and providing crucial time for evacuation.
      • Robust & Secure Construction: Manufactured from heavy-gauge galvanized steel, offering exceptional durability and resistance to impact, forced entry, and harsh environments. Multi-point locking mechanisms enhance security when the door is closed.
      • Weather Resistance: Fully sealed and insulated options provide excellent weather protection, making them suitable for both internal and external applications, preventing drafts and reducing energy costs.
      • Anti-Jemmy Hinge Bolts: Additional security features like dog bolt hinges prevent the door from being forced open even if the hinges are attacked.
      • Adjustable Overhead Door Closer: Ensures the door consistently and reliably closes after use, critical for maintaining fire integrity and building security. (Conforms to EN 1154).
      • Intumescent & Smoke Seals: Integrated within the frame, these seals expand under heat to block the passage of fire and smoke, significantly enhancing safety.
      • Versatile Design & Finish: Available in a range of standard and custom sizes, with options for vision panels, louvers, and a wide array of powder-coated RAL colors to match your building's aesthetics.
      • DDA Compliant Thresholds: Low-profile thresholds available to ensure accessibility for all users, including those with disabilities, in line with DDA regulations.

      Technical Specifications

      FeatureDetail
      Door Leaf MaterialHigh-grade galvanized steel, typically 1.2mm to 1.5mm thick (double-skinned, folded construction).
      Frame MaterialHeavy-duty galvanized steel, 1.5mm to 2.0mm thick, supplied as a fully welded or knock-down frame.
      Fire Rating OptionsFD30, FD60, FD90, FD120 (BS EN 1634 tested and certified).
      Panic HardwareCE marked, EN 1125 compliant push bar or crash bar (rim, mortice, or vertical bolt options).
      HingesHeavy-duty, CE marked, stainless steel butt hinges (min. 4 per leaf), often with dog bolts for security.
      Door CloserOverhead, adjustable, CE marked door closer (EN 1154 compliant) for reliable closing.
      SealsFactory-fitted intumescent strips and cold smoke seals.
      InsulationMineral wool or fire-resistant core for thermal and acoustic insulation.
      FinishesStandard powder-coated finish in a wide range of RAL colors. Primed finishes available for on-site painting.
      SizesStandard single and double door configurations. Custom sizes available upon request.
      Vision PanelsOptional fire-rated glazing options (e.g., Pyroguard, Pyran) with various designs and obscurity levels.
      ThresholdLow-profile, DDA compliant threshold options.
      HandingLeft-hand or right-hand opening, inward or outward opening.

      Ideal Applications

      Our Fire Exit Doors are essential for ensuring safety and compliance across a wide range of sectors:

      • Commercial Buildings & Offices
      • Industrial Facilities & Warehouses
      • Schools, Universities & Educational Institutions
      • Hospitals & Healthcare Facilities
      • Retail Stores & Shopping Centers
      • Hotels & Accommodation
      • Public Assembly Buildings (Theatres, Sports Arenas)
      • Multi-Unit Residential Buildings (e.g., apartment blocks)

      Compliance & Certifications

      Our Fire Exit Doors are rigorously tested and certified to meet or exceed the following critical standards:

      • BS EN 1634: Fire resistance and smoke control tests for door and shutter assemblies.
      • BS EN 1125: Panic exit devices for emergency exits operated by a horizontal bar.
      • CE Marking: Conforming to European directives and ensuring product quality and safety.
      • Building Regulations (Part B): Meeting the fire safety requirements outlined in national building codes.
      • DDA Compliance (optional): Designed to ensure accessibility for all users.

      Tags: Fire Exit Door