landing valves

      Description


      Landing Valves: Reliable & Robust Fire Safety Connection Points

      Ensure immediate and effective firefighting capability with our premium range of Landing Valves. As a critical component of any building's fixed fire suppression system, our landing valves are meticulously engineered to provide a readily accessible and controlled water supply from a fire riser main directly to a fire hose, enabling rapid response in emergency situations.

      Designed for unwavering performance under pressure, our landing valves are built from high-quality, corrosion-resistant materials and comply with the strictest international safety standards. They are an indispensable asset for protecting lives and property across diverse environments.

      Key Features

      • Robust Construction: Manufactured from durable materials such as Gunmetal, Brass, or Ductile Iron, ensuring long-term reliability and resistance to wear and tear.
      • High-Pressure Resilience: Engineered to withstand and perform flawlessly under high working pressures common in fire suppression systems.
      • Smooth & Controlled Operation: Features a precision-machined spindle and disc assembly for effortless opening and closing, allowing for precise water flow control.
      • Leak-Proof Design: Incorporates high-quality sealing components (e.g., EPDM, NBR) to guarantee a tight, leak-free connection and prevent water wastage.
      • Corrosion Resistance: Materials and coatings are selected to resist corrosion from water and environmental factors, ensuring longevity and consistent performance.
      • Standard Compliant: Meets or exceeds relevant international and local fire safety standards, ensuring full compliance for your projects.
      • Versatile Connections: Available with various inlet and outlet connection types to seamlessly integrate with existing or new fire hose systems worldwide.
      • Low Maintenance: Designed for minimal maintenance requirements, providing peace of mind and reducing operational costs.

      Benefits

      • Uncompromised Safety: Provides a dependable water source for firefighting, significantly enhancing emergency response capabilities and protecting occupants and assets.
      • Regulatory Compliance: Ensures your facility meets essential fire safety codes and regulations, avoiding penalties and fostering a safe environment.
      • Durability & Longevity: Invest in a product designed to last, reducing the need for frequent replacements and offering excellent return on investment.
      • Ease of Use: Simple and intuitive operation allows firefighters and trained personnel to quickly and efficiently deploy hoses when every second counts.
      • Global Compatibility: Our range of connection types ensures compatibility with a wide array of fire hose couplings and systems around the world.

      Technical Specifications

      • Type: Screw Down Globe Type (Angle or Straight Pattern)
      • Nominal Size: DN50, DN65, DN80 (2", 2.5", 3")
      • Inlet Connection:
        • Flanged: PN10, PN16, ANSI 150#
        • Screwed: BSPT, NPT
        • Grooved
      • Outlet Connection:
        • Instantaneous Male: BS 336 Type A/B, G50/G65
        • Storz: C, B
        • NH (NST): 1.5", 2.5"
        • GOST
        • JIS
      • Working Pressure: Up to 16 bar (232 psi)
      • Test Pressure:
        • Body: 22.5 bar (hydrostatic)
        • Seat: 16.5 bar (hydrostatic)
      • Operating Temperature Range: -10°C to +60°C
      • Flow Rate: High flow capacity for effective water delivery

      Materials of Construction

      • Body & Cover:
        • Gunmetal (Bronze, e.g., LG2, C83600)
        • Brass (e.g., CW617N, C37700)
        • Ductile Iron (EN GJS-400-15 with corrosion-resistant epoxy coating)
      • Spindle: Brass, Stainless Steel (e.g., SS304, SS316)
      • Valve Disc: Brass, Gunmetal, or Ductile Iron with replaceable rubber facing (EPDM, NBR)
      • Handwheel: Grey Cast Iron, Aluminium, or Durable Thermoplastic
      • Gaskets & O-Rings: EPDM, NBR
      • Seat Ring: Brass, Gunmetal, or Stainless Steel

      Applications

      Our Landing Valves are essential for fixed fire protection systems in a wide variety of buildings and facilities, including:

      • High-Rise Residential Buildings
      • Commercial & Office Complexes
      • Industrial Plants & Factories
      • Warehouses & Logistics Centres
      • Hospitals & Healthcare Facilities
      • Educational Institutions
      • Shopping Malls & Public Venues
      • Hotels & Hospitality Sector
      • Marine Vessels & Offshore Platforms

      Standards & Certifications

      Our Landing Valves are designed and manufactured in accordance with, or certified to, leading international standards such as:

      • BS 5041 Part 1: Fire Hydrant Systems and Equipment - Landing Valves (Screw Down Type)
      • EN 671-2: Fixed Firefighting Systems - Hose Systems with Flat Hoses
      • UL Listed / FM Approved: (Available for specific models to North American standards)
      • ISO 9001: Quality Management System Certified Manufacturing

      Tags: landing valves