Power Distribution Panel

      Description


      Intelligent Power Distribution Unit (PDU): Optimize & Protect Your Critical Infrastructure

      Revolutionize how you power and manage your critical IT infrastructure with our advanced Intelligent Power Distribution Unit (PDU). Designed for the rigorous demands of modern data centers, server rooms, and network closets, this PDU delivers unparalleled power distribution, real-time monitoring, and remote management capabilities, ensuring maximum uptime, efficiency, and security for your valuable equipment.

      Key Features & Benefits

      • Real-time Energy Monitoring: Track power consumption (Amps, Volts, Watts, kWh, Power Factor) at the PDU, phase, or individual outlet level.
      • Remote Management: Securely monitor and control outlets from anywhere via a web interface, SNMP, or CLI.
      • Switched Outlets: Power cycle, turn on/off, or sequence outlets remotely to conserve energy, reboot hung equipment, or manage power events.
      • Advanced Safety: Built-in overload protection, surge suppression, and robust grounding ensure equipment safety.
      • Environmental Monitoring: Integrate optional temperature and humidity sensors for comprehensive rack-level environmental awareness.
      • Flexible Design: Available in various form factors (0U vertical, 1U/2U horizontal) and outlet configurations to fit any rack environment.
      • Alarm & Notification System: User-definable thresholds trigger alerts via email, SNMP traps, or syslog for proactive issue resolution.
      • High Reliability: Constructed with premium-grade components for continuous, dependable operation.

      Detailed Product Breakdown

      1. Superior Power Distribution & Performance

      • High-Density Outlet Options: Available with a wide array of IEC (C13, C19), NEMA, or country-specific outlets to accommodate diverse equipment needs.
      • Robust Input Capabilities: Supports single-phase (120V, 208V, 230V) and three-phase (208V, 400V) configurations, with current ratings from 16A to 60A.
      • Phase Balancing (for 3-Phase Models): Intelligently distributes loads across phases to prevent overloads and optimize power utilization.
      • High-Grade Components: Engineered with durable materials and high-quality circuit breakers for long-term reliability and safety.

      2. Intelligent Monitoring & Management

      • Comprehensive Metering:
        • Current (Amps): Monitor real-time current draw to prevent overloads and optimize load balancing.
        • Voltage (Volts): Ensure stable power delivery and detect voltage fluctuations.
        • Active Power (kW): Track instantaneous power consumption.
        • Energy (kWh): Measure cumulative energy usage for accurate billing, efficiency analysis, and PUE calculations.
        • Power Factor: Understand power quality and identify potential inefficiencies.
        • Optional Outlet-Level Metering: Gain granular insights into individual device power consumption.
      • Network Connectivity: Features an integrated Ethernet port for network access, supporting TCP/IP, HTTP/HTTPS, SNMP (v1/v2c/v3), SMTP, NTP, Syslog, and Telnet/SSH.
      • User-Friendly Interface: Intuitive web-based GUI provides easy access to real-time data, configuration settings, and event logs.
      • Threshold Alarms: Set custom thresholds for current, voltage, temperature, and humidity. Receive instant notifications via email, SNMP traps, or syslog when thresholds are exceeded or critical events occur.
      • Data Logging & Reporting: Store historical power data for trend analysis, capacity planning, and auditing purposes.

      3. Enhanced Safety & Protection

      • Integrated Overload Protection: Resettable hydraulic-magnetic circuit breakers safeguard against overcurrent conditions, preventing damage to connected equipment and the PDU itself.
      • Surge Suppression (Optional/Select Models): Protects sensitive electronics from power spikes and transient voltages.
      • Secure Access: Multi-level user authentication, IP access control, and SSL encryption ensure secure remote management.
      • Environmental Resilience: Designed to operate reliably within a wide range of data center temperatures and humidity levels.
      • Robust Grounding: Provides essential safety grounding for all connected devices.

      4. Flexible Design & Easy Deployment

      • Versatile Form Factors:
        • 0U Vertical (Rack Mount): Mounts vertically in the rear or side of a rack, saving valuable rack space for IT equipment.
        • 1U/2U Horizontal (Rack Mount): Fits standard 19-inch racks, ideal for distributing power across a single rack unit.
      • Toolless Mounting Options: Many models support quick and easy toolless installation, reducing deployment time.
      • Local Display: Clear LCD or LED display provides instant access to PDU status, metering data, and network information at the rack.
      • Input Plug Options: Available with various input plug types (e.g., L6-30P, L21-30P, 3-Phase NEMA, IEC 60309) to match your facility's power infrastructure.

      5. Scalability & Integration

      • Daisy Chaining (Select Models): Reduce network port usage by connecting multiple PDUs via a single IP address.
      • DCIM Software Integration: Seamlessly integrates with leading Data Center Infrastructure Management (DCIM) platforms for centralized power monitoring, asset management, and capacity planning.

      Ideal Applications

      • Enterprise Data Centers: Achieve granular power monitoring and control for mission-critical operations.
      • Colocation Facilities: Offer metered power services to tenants and optimize energy usage.
      • Server Rooms & Network Closets: Efficiently power and protect essential networking and compute equipment.
      • Edge Computing Environments: Provide reliable and remotely manageable power in distributed IT setups.
      • Telecommunications Shelters: Ensure stable power and remote oversight in remote locations.
      • Test & Development Labs: Accurately track power consumption for equipment testing and analysis.

      Technical Specifications (Example)

      FeatureSpecification (Common Examples)
      Input Voltage100-240V AC (Single Phase), 208/120V AC, 400/230V AC (Three Phase)
      Input Current16A, 20A, 30A, 32A, 50A, 60A per phase
      Input Plug TypeNEMA L5-20P, L6-30P, L21-30P, IEC 60309 (16A, 32A), Hardwired
      Output Outlets8 to 42 outlets, including C13, C19, NEMA 5-15R, 5-20R, L5-20R, L6-20R, etc.
      Form Factor0U Vertical (Up to 70 inches), 1U/2U Horizontal (19-inch rackmount)
      Metering Accuracy+/- 1% (Revenue Grade options available)
      Network ProtocolsHTTP/HTTPS, SNMP (v1/v2c/v3), SSH, Telnet, Syslog, NTP, SMTP (Email Alerts)
      Environmental Ports2-4 RJ-45 ports for optional temperature, humidity, dry contact sensors
      Operating Temp.0°C to 60°C (32°F to 140°F)
      CertificationsUL, CE, RoHS, FCC Part 15 Class A
      DisplayLocal LCD or LED with push-button navigation
      MountingToolless buttons, brackets included for vertical or horizontal mounting

      Empower your data center with intelligent power management. Our Power Distribution Unit is more than just a power strip; it's a critical component for optimizing performance, ensuring reliability, and maximizing efficiency in your dynamic IT environment.

      Contact us today to discuss your specific power distribution needs and find the perfect PDU solution for your infrastructure!

      PLC Panel

      Drive Panel

      APFC Panel

      Tags: Power Distribution Panel