Are you experiencing high energy bills, equipment overload, or penalties from your utility provider due to poor power quality? Low power factor is a silent energy thief, costing businesses significant amounts annually. Our advanced Automatic Power Factor Correction (APFC) Panels are engineered to eliminate this inefficiency, ensuring optimal power utilization, reducing operational costs, and extending the lifespan of your valuable electrical equipment.
An APFC Panel is a sophisticated electrical control system designed to automatically detect and correct the power factor of an electrical load. By continuously monitoring the reactive power in your system, it intelligently switches capacitor banks ON or OFF to maintain the power factor as close to unity (1.0) as possible. This optimization translates directly into tangible savings and improved electrical system performance.
| Parameter | Specification Range |
|---|---|
| Rated Output (kVAr) | 50 kVAr to 1000 kVAr (standard models), higher ratings available on request |
| Rated Voltage | 415V AC, 3-Phase, 50/60 Hz (Standard); 690V, 3.3kV, 6.6kV, 11kV options available |
| Frequency | 50 Hz / 60 Hz |
| Target Power Factor | Adjustable from 0.95 Lagging to 0.99 Lagging / Unity |
| Control Type | Microprocessor-based, Automatic Stepped Correction |
| Number of Steps | 4, 6, 8, 12, 16 steps (or customized) |
| Capacitor Type | Heavy Duty MPP (Metalized Polypropylene) - Self-healing, Dry Type |
| Capacitor Life | >100,000 hours |
| Switching Type | Contactor Switched (Standard); Thyristor Switched (for dynamic loads) |
| Harmonic Filtering | Optional Detuned Reactors (7%, 14% de-tuning factor) |
| Enclosure Material | CRCA Sheet Steel |
| IP Protection | IP4X (Standard), IP54, IP65 (Optional) |
| Cooling | Natural Air Cooled (Standard), Forced Air Cooled with Fans (for higher ratings) |
| Indications | Healthy, Fault, Power Factor (digital display), Voltage, Current, Frequency, kW, kVA, kVAr |
| Protection | Overcurrent, Overload, Short Circuit, Over-voltage, Under-voltage, Over-temperature, Phase Failure/Sequence, Short Circuit on Capacitor Banks |
| Operating Temperature | -10°C to +50°C |
| Relative Humidity | Up to 95% non-condensing |
| Standards | IEC 61921, IEC 60831-1 & 2, IS 13585, EN 61439-1 |
| Communication | Optional Modbus RTU (RS485) |
Our APFC Panels are essential for any facility with significant inductive loads, including:
Don't let poor power factor drain your profits! Invest in our APFC Panel solutions and take control of your energy costs.
Contact us today for a free consultation and a customized quote. Let our experts help you achieve optimal power quality and maximize your savings.